Laatst bijgewerkt op
3 mei 2021
Country
Canada
Issue
Siteadmin does not list all the pages on publish instance.
Cause
Debugging in browser shows that https://<AEM instance>/libs/wcm/core/content/siteadmin.infinity.json return http 300 Multiple Choices.
Resolution
To enable the Json response to come through, configure JSON Max results to higher value.
http://<AEM-Instance>/system/console/configMgr/org.apache.sling.servlets.get.DefaultGetServlet.